Spring Lock Coupling

            0

1.
NOTE: Select the special tool appropriate for the line diameter.


Install the special tool.
  • Install the special tool so that the inner ring can be guided into the clamping spring.



2. Press the special tool into the clamp spring.



3. Disconnect the refrigerant line.
  • Discard the O-rings.



4. Connect the refrigerant line.
  • Check the clamp spring for damage.
  • Carefully remove any damaged clamp springs using a thin piece of wire and install new springs.



5.
NOTE: Clean connections using cutting oil and a lint-free cloth.


Press the indicator ring into the clamp spring.



6.
NOTE: Install new refrigerant line O-rings.


NOTE: Apply clean refrigeration oil to the O-rings of the refrigerant lines before installation.


Connect the refrigerant lines.
  • Check that the clamping spring is properly secured.