Disassembly
1. Release the ventilation hose at floor level. Disconnect the hose.

2. Disconnect the heater/heat exchanger housing sections.
- Remove two bolts.
- Release the seven clamps.

3. Remove the heat exchanger.

4. Remove the heat exchanger.

5. Disconnect the heater/blower housing sections.
- 1. Remove two bolts.
- 2. Release the four fasteners.

6. Disconnect the air blower/recirculation fan housing sections.
- Release the nine fasteners.

7. Disassemble the air recirculation housing. Release the five fasteners.

8. Remove the air deflector.

9. Disconnect the heater/evaporator housing. Release the eleven fasteners.

Assembly
1.
NOTE: During assembly, check that the guide pins are positioned correctly.
NOTE: If the housing was not properly sealed during assembly or the fasteners were broken, use steel clamps as replacements.
Install the elements back in place in reverse order.