1. Disconnect the wire from the negative terminal of the battery.

2. Remove the power steering fluid reservoir mounting bolt and move the reservoir to the side.

3. Remove the generator terminal protective cap.

4. Loosen the fastening nut and disconnect the wire tip from the generator terminal, squeeze the retainer and disconnect the wiring harness block from the generator.


Fig. 10.3. Generator mounting: 1 – upper generator mounting bolt; 2 – generator mounting stud; 3 – nut; 4 – protective shield; 5 – lower generator mounting bolt
5. Unscrew nut 3 (Fig. 10.3) securing the generator.

6. Unscrew the upper bolt 1 of the generator mount and remove the protective shield 4.
7. Remove the accessory drive belt (see "Replacing the accessory drive belt").
8. Unscrew the lower generator mounting bolt 5, stud 2 and remove the generator from the engine compartment.
9. Install the generator in the reverse order of removal, replacing the accessory drive belt with a new one (see "Replacing the accessory drive belt").