Withdrawal
1. Raise and support the vehicle. See Section 100-02 for more information.
2. Disconnect the high pressure switch electrical connector.
3.
NOTE: Make sure the high pressure switch valve closes completely after removing the high pressure switch to prevent loss of refrigerant.
Remove the high pressure switch.
- Discard O-rings of circular cross-section.
Installation
1.
NOTE: Install new high pressure switch o-rings.
NOTE: Coat the O-rings on the high pressure switch with clean coolant oil before installation.
To install, follow the removal procedure in reverse order.