Contents: Coolant capacity ↳ Pressure in the system ↳ Expansion tank cap ↳ Thermostat ↳ Coolant temperature sensor ↳ Radiator Fan Switch Temperature… ↳ Air conditioning system ↳ Tightening moments ↳
Coolant capacity
HSC and Endura-E engines with a working volume of 1.3 dm³ - 7.1 dm³
CVH engines with a working volume of 1.4 dm³ - 7.6 dm³
CVH engines with a working volume of 1.6 dm³ - 7.8 dm³
RTE engines with a working volume of 1.4 dm³ - 7.6 dm³
Zetec engines with a working volume of 1.6 and 1.8 dm³ - 7.4 dm³
Zetec-E engines with a working volume of 1.6 and 1.8 dm³ - 7.0 dm³
Pressure in the system
Cooling system test pressure 1.2 bar for 10 seconds
Expansion tank cap
Opening pressure of the bypass valve - 1.2 bar
Thermostat
Temperature of the beginning of opening - 85-89°C
Full thermostat opening temperature - 102°C
Coolant temperature sensor
Sensor resistance at temperature:
- 0°C - 89-102 kOhm
- 20°C - 35-40 kOhm
- 100°C - 1.9-2.5 kOhm
- 120°C - 1.0-1.4 kOhm
Radiator Fan Switch Temperature Sensor
Version without catalyst:
- switch-on temperature - 99°C
- switch-off temperature - 94°C
Version with catalyst:
- switch-on temperature, 1st stage - 100°C
- switch-off temperature. 1 stage - 94°C
- switch-on temperature. 2nd stage - 110°C
- switch-off temperature. 2nd stage - 105°C
Air conditioning system
Reagent type - R12 or R134A
Tightening moments
| Thermostat | |
| — HCS and Endura-E engines | 20 Nm |
| - CVH engine | 11 Nm |
| — Zetec and Zetec-E engines | 20 Nm |
| Water pump pulley | 10 Nm |
| Water pump mounting bolts | |
| — HCS and Endura-E engines | 8 Nm |
| — CVH and RTE engines | 8 Nm |
| — Zetec and Zetec-E engines | 18 Nm |
| Coolant Temperature Gauge Sensor | 6 Nm |
| Coolant temperature sensor | |
| — HCS engine | 23 Nm |
| - CVH engine | |
| - with a working volume of 1.4 dm³ | 19 Nm |
| - with a working volume of 1.6 dm³ | 15 Nm |
| - RTE engine | 15 Nm |
| — Zetec and Zetec-E engines | 15 Nm |
| Radiator mounting bolts | 23 Nm |
| Cooling fan to the casing | 10 Nm |
| Cooling fan to radiator | 4 Nm |
| Heater housing | 9 Nm |
| Elements of the air conditioning system | |
| Capacitor | 9 Nm |
| Radiator casing | 4 Nm |
| Water separator for radiator hanger | 4 Nm |
| Pressure sensor | 15 Nm |
| Expansion valve to evaporator | 4 Nm |
| Air conditioner | 6 Nm |
| Pipes to the compressor | 23 Nm |
| Low pressure pipe to expansion valve | 6 Nm |
| Connecting pipe of water separator to condenser | 17 Nm |
| Pipes to the water separator | 17 Nm |
| Compressor to suspension | 24 Nm |
| Compressor drive plate | 14 Nm |
This article was borrowed from the website www.fordbook.ru