Technical specifications (Escort 5)

            0

Coolant capacity


HSC and Endura-E engines with a working volume of 1.3 dm³ - 7.1 dm³

CVH engines with a working volume of 1.4 dm³ - 7.6 dm³

CVH engines with a working volume of 1.6 dm³ - 7.8 dm³

RTE engines with a working volume of 1.4 dm³ - 7.6 dm³

Zetec engines with a working volume of 1.6 and 1.8 dm³ - 7.4 dm³

Zetec-E engines with a working volume of 1.6 and 1.8 dm³ - 7.0 dm³

Pressure in the system


Cooling system test pressure 1.2 bar for 10 seconds

Expansion tank cap


Opening pressure of the bypass valve - 1.2 bar

Thermostat


Temperature of the beginning of opening - 85-89°C

Full thermostat opening temperature - 102°C

Coolant temperature sensor


Sensor resistance at temperature:
  • 0°C - 89-102 kOhm
  • 20°C - 35-40 kOhm
  • 100°C - 1.9-2.5 kOhm
  • 120°C - 1.0-1.4 kOhm

Radiator Fan Switch Temperature Sensor


Version without catalyst:
  • switch-on temperature - 99°C
  • switch-off temperature - 94°C

Version with catalyst:
  • switch-on temperature, 1st stage - 100°C
  • switch-off temperature. 1 stage - 94°C
  • switch-on temperature. 2nd stage - 110°C
  • switch-off temperature. 2nd stage - 105°C

Air conditioning system


Reagent type - R12 or R134A

Tightening moments


Thermostat
— HCS and Endura-E engines20 Nm
- CVH engine11 Nm
— Zetec and Zetec-E engines20 Nm
Water pump pulley10 Nm
Water pump mounting bolts
— HCS and Endura-E engines8 Nm
— CVH and RTE engines8 Nm
— Zetec and Zetec-E engines18 Nm
Coolant Temperature Gauge Sensor6 Nm
Coolant temperature sensor
— HCS engine23 Nm
- CVH engine
- with a working volume of 1.4 dm³19 Nm
- with a working volume of 1.6 dm³15 Nm
- RTE engine15 Nm
— Zetec and Zetec-E engines15 Nm
Radiator mounting bolts23 Nm
Cooling fan to the casing10 Nm
Cooling fan to radiator4 Nm
Heater housing9 Nm
Elements of the air conditioning system
Capacitor9 Nm
Radiator casing4 Nm
Water separator for radiator hanger4 Nm
Pressure sensor15 Nm
Expansion valve to evaporator4 Nm
Air conditioner6 Nm
Pipes to the compressor23 Nm
Low pressure pipe to expansion valve6 Nm
Connecting pipe of water separator to condenser17 Nm
Pipes to the water separator17 Nm
Compressor to suspension24 Nm
Compressor drive plate14 Nm