Cooling system — specifications (Escort 4)

            0

Coolant



Coolant replacement: once every two years.

The ratio of Ford concentrate and water for preparing a coolant that works at temperatures down to minus 30°C
50/ 50 %
Opening pressure of the valve in the plug on the thermostat housing
0.85 – 1.10 bar

Thermostat



Type: wax filled.

Temperature of opening start
85 – 89°C
Full opening temperature
99 – 102°C

Water pump



Type: centrifugal with V-belt drive.

Cooling system capacity



OHV engine with a working volume of 1.1 dm³
5.3 dm³
OHV engine with a working volume of 1.1 dm³
6.2 dm³ with small radiator or 7.2 dm³ with large radiator
Engines with a working volume of 1.3 dm³
7.1 dm³