Coolant
Coolant replacement: once every two years.
| The ratio of Ford concentrate and water for preparing a coolant that works at temperatures down to minus 30°C | 50/ 50 % |
| Opening pressure of the valve in the plug on the thermostat housing | 0.85 – 1.10 bar |
Thermostat
Type: wax filled.
| Temperature of opening start | 85 – 89°C |
| Full opening temperature | 99 – 102°C |
Water pump
Type: centrifugal with V-belt drive.
Cooling system capacity
| OHV engine with a working volume of 1.1 dm³ | 5.3 dm³ |
| OHV engine with a working volume of 1.1 dm³ | 6.2 dm³ with small radiator or 7.2 dm³ with large radiator |
| Engines with a working volume of 1.3 dm³ | 7.1 dm³ |
(The original article is posted at: Fordbook.ru)