SEQUENCE OF WORKS
1. Disconnect the cable from the negative terminal of the battery.
2. Remove the radio.

Fig. 16.4. Location of screws (1) and fasteners (2) for fastening the heating and ventilation control unit
3. Remove screws 1 (Fig. 16.4).
4. Release the clamps 2.
5. Carefully pull the heating and ventilation control unit forward and disconnect the central contact connector from the back of the unit.

Fig. 16.5. Air flow distribution cable attachment point
6. Disconnect the air flow distribution cable from the heating and ventilation control unit (Fig. 16.5).
7. Remove the heating and ventilation control unit.
8. Installation is carried out in the reverse order of removal.
9. Connect the cable to the negative terminal of the battery.
10. Check the operation of the heating and ventilation system.